On FlexNet®?
Keep it.
RG3 Perpetual PD meters with a Sensus-approved Optical Encoder and a Sensus-compatible touch coupler. Plug into your SmartPoint® radios and keep reading on FlexNet®.

Same network. Better meter.
- Sensus-approved RG3 Optical Encoder, approved for SmartPoint® radios
- Sensus-compatible touch coupler (part EP-TRPL), ready to plug in
- RG3 Perpetual PD meter, 5/8, 3/4 and 1 inch, low lead
- SR® II style oscillating piston chamber in a boltless brass case
- All-silicone seals that stand up to chloramine
- Available with a single check for backflow prevention
Order by the box or the pallet.
Perpetual PD with a Sensus-approved Optical Encoder and touch coupler, ready for SmartPoint®. Create a free account at checkout and order today.
5/8 x 3/4 in
Plastic bottom, gallons, Optical Encoder, touch coupler
- Box of 10 meters
- Volume discounts on pallet quantities (300). Ask us.
- Single meter $224.31
5/8 x 1/2, 3/4 and 1 in
Pricing available on these sizes too, plus brass or cast iron bottoms, cubic feet registers and single check valves. Tell us what you need.
Prices in USD, before tax and shipping. Box pricing applies to orders of 10 or more. Volume discounts available on pallet quantities. Prices may change.
The 25-year meter.
American Water's field data from Kansas City Water Services tested in-service PD meters out to 30 years. Most still tested near 100% accuracy past year 25.
A static meter runs on a sealed battery. When the battery is done, the meter is done. The Perpetual's Optical Encoder has no battery to run out.
Sources: Hughes, D. (American Water), "Getting Smarter with Advanced Metering Infrastructure," Bentley Be Conference, May 19, 2010, Slide 9, data courtesy Kansas City Water Services Dept. Hannah, C.C., P.E., Static Meter Research Project, Johnson Controls, Q2 2026 update, Olathe, KS site (21 active services, Dec 2010 to Jun 2026). Battery figures: manufacturer datasheets, compiled in 15 Years of Field Data. Field results describe PD meters as a class, not one brand.
Compare before you switch.
If you are looking at a Sensus iPERL® or iPERL 2 to replace aging SR® II meters, you have another option that stays on your FlexNet® system: a positive displacement meter built so the chamber doesn’t wear.
Weighing static meters against PD? Read what 15 years of field data from the Static Meter Research Project shows.
Bolts bend chambers. We removed them.
SR® II style meters lose low flow when uneven bolt torque bends the chamber and the piston starts to rub. The Perpetual case compresses the chamber evenly all the way around, so it doesn’t.
360° compression
Even force on the chamber, no bolts to back off or over-tighten.
Silicone cradle
The chamber sits in 100% silicone, top and bottom.
Oversized outlet gasket
Seals against machined brass to stop bypass.
Holds low flow
No rub means no wear spots and no slow drift.
Sensus compatibility FAQ.
Can my utility try an RG3 meter before buying?
Yes. Qualified utilities can get their first sample meter for $49 to test on their own system. One per utility. Contact us to request one.
How long does a PD meter last compared to an iPERL?
Field data from American Water and Kansas City Water Services shows most PD meters still testing near 100% accuracy past 25 years in service. A static meter such as the iPERL runs on a sealed battery that Sensus specifies at 20 years in North America and 15 years internationally, and the meter is replaced when the battery ends. In a 15-year side-by-side study in Olathe, Kansas, an iPERL and a Sensus SR II PD meter registered within 0.19% of each other.
Does RG3 make a Sensus-compatible water meter?
Yes. The RG3 Perpetual PD meter (5/8, 3/4 and 1 inch) is sold with a Sensus-approved RG3 Optical Encoder and a Sensus-compatible touch coupler, part EP-TRPL.
Will RG3 meters work with Sensus SmartPoint and FlexNet?
Yes. RG3 Optical Encoders are approved by Sensus for use with SmartPoint® radios, and the touch coupler integrates with the FlexNet® communication network.
Is RG3 an alternative to the Sensus iPERL or iPERL 2?
If you are pricing an iPERL® or iPERL 2 and want to stay on your FlexNet® system, the RG3 Perpetual PD meter with a Sensus-approved encoder is a positive displacement option that reads on the same network. Ask us for a side-by-side quote.
Can I replace Sensus SR II meters with RG3 meters?
Yes. RG3 PD meters use an SR® II style oscillating piston chamber, and some RG3 parts, like the PD housing and ring, also fit Sensus SR series meters. The Perpetual adds a boltless 360° main case so the chamber is not distorted by bolt torque.
What is a touch coupler?
A touch coupler is the pad on the meter lid that a handheld or radio reads through. RG3’s touch coupler is Sensus-compatible and ships ready to plug in.
Is RG3 affiliated with Sensus?
No. RG3 Meter Company is an independent, family-owned manufacturer in Longview, Texas. Sensus, FlexNet, SmartPoint, iPERL and SR II are trademarks of their respective owners.
RG3 Meter Company is not affiliated with Sensus. Sensus, FlexNet, SmartPoint, iPERL and SR II are trademarks of their respective owners.