Skip to Content
Gas Pressure Monitoring

Know your gas pressure.
Around the clock.

Watch pressure at regulator stations and across your gas system. High and low alarms in Tesla MDM, with texts to the people you choose.

High / Low AlarmsText AlertsPressure HistoryGas and Water in One System
REGULATOR STATION 4 · OUTLETHIGH LIMITLOW LIMITPRESSURE HIGHText sent to your crewGas system pressure, alarms in Tesla MDM.
Instant
alarm when a reading crosses your limit
2
limits you set: high and low
24/7
watch from the office
1
Tesla MDM for gas and water
What it catches

Pressure is safety.

Over-pressureCatch a regulator that fails open before pressure climbs past your limit.
Under-pressureSpot a regulator that is failing closed or starving a district.
Cold-weather demandSee pressure sag at the far end of the system on the coldest days.
Regulator healthInlet and outlet readings show how each station is holding set point.
Line damageA sudden drop can point to a hit or broken line.
Pressure recordsEvery reading logged in Tesla MDM for reports and regulators.
Where it goes

Four places that matter.

1
Regulator stationsInlet and outlet.
2
District regulatorsEvery pressure district you feed.
3
End of the systemWhere pressure runs lowest on a cold day.
4
Large servicesCommercial and industrial customers.
How it works

Three steps.

1
Set the sensor

Mount it where you want to watch pressure.

2
Report to Tesla MDM

Readings land in the same software that reads your meters.

3
Set your limits

Tesla MDM alarms immediately when a reading goes high or low, and texts the staff you choose.

Read your gas meters tooThe Tesla UGI index retrofits diaphragm and rotary meters, and can replace a volume corrector on elevated-pressure services. Tesla UGI · Corrector Alternative
Run water too?Watch water pressure in the same Tesla MDM. Water Pressure Monitoring
Questions

Gas pressure FAQ.

How does RG3 gas pressure monitoring work?

Pressure sensors on your gas system report to Tesla MDM. When a reading goes above or below the limits your utility sets, Tesla MDM raises an alarm immediately and texts the staff you choose.

Where should gas pressure be monitored?

Common spots are regulator station inlets and outlets, district regulator outlets, the far end of the system where pressure runs lowest, and large commercial services.

Can I see gas and water pressure in the same system?

Yes. Gas and water pressure, along with gas and water meter reads, can all live in one Tesla MDM with one login.

Does RG3 also read gas meters?

Yes. The Tesla UGI index retrofits diaphragm and rotary gas meters and reports to Tesla MDM.

Watch every regulator.
From one screen.